Applied Environmental Research

Publication Date

2021-04-01

Abstract

This study assesses the efficiency of using ozone technology to treat iron from groundwater while hardness acts as a radical scavenger. Batch experiments were conducted to determine the effects of initial pH 6, 7 and 8, and hardness of 300, 400 and 500 mg L-1 and kinetic analysis. The optimum conditions were found to be initial pH of 8 and hardness of 300 mg L-1. The removal efficiency of iron by ozonation was 99.97%, which was higher than that of air without ozone applied (83.67%). However, the presence of hardness and tert-butanol (TBA) had a negative effect on the oxidation of iron from groundwater. By increasing the carbonate hardness concentration, the oxidation rate of iron by ozone was reduced. The results of kinetic analyses indicated that the reactions of ozonation to remove iron from groundwater followed a pseudo-first order kinetic model with a rate constant of 0.0881 min-1, while air without ozone applied (aeration) was 0.0051 min-1. This finding suggests the potential use of ozone to remove iron from groundwater. Iron concentration from groundwater samples treated by ozonation have met the World Health Organization (WHO) guidelines (0.3 mg L-1).

DOI

10.35762/AER.2021.43.2.8

First Page

106

Last Page

115

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.