Applied Environmental Research
Publication Date
2015-01-01
Abstract
This studycompared thecontamination of the chemotherapeutic agent cyclophosphamide between using a conventional admixing procedure and closed system transfer devices (CSTDs). Surface wipes and urine samples were collected for two weeks before and two weeks after the CSTDs were used. The surface wipe samples were collected from critical areas in an aseptic dispensary unit and a chemotherapy patient care unit. The urine samples were collected from healthcare workers. Contamination from cyclophosphamide in the surface wipe samples was detected in fewer areas following the implementation of CSTDs. The mediancyclophospha-mide concentration in aseptic dispensary unit areas following the usage of CSTDs was significantlylower than what was detected when the conventional method (p=0.036, Mann-Whitney's U-test) was used.Cyclophosphamide contamination was not detected in critical areas of the patient care unit following the use of the CSTDs.This study demonstrates the potential advantages of utilizingCSTDs to reduce contamination from chemotherapeutic agents in a work setting.