NAKHARA (Journal of Environmental Design and Planning)

Publication Date

2023

Abstract

This research investigates practical methods to improve the efficiency of natural ventilation in residential units of multi-family high-rises without additional areas. Typical studio- and one-bedroom-types of small units were redesigned using: 1) air post, 2) transom window, 3) buffer space with one corridor opening and 4) buffer space with two corridor openings. The simulation study using a CFD program to reveal that the indoor average air velocity coefficient (Cv ) in the best redesigned case (0.46) significantly improves from the base case (0.01). The paper demonstrates an example of application to an actual climate in Bangkok, Thailand. It was found that the proposed redesign using buffer spaces can considerably help upgrade the living conditions of the occupants in terms of both thermal comfort (24 hours vs. 0 hours in the comfort zone per day) and indoor air quality (24 hours vs. 8–17 hours that pass the minimum ventilation requirement per day) in the transitional month of February.

DOI

10.54028/NJ202322315

First Page

1

Last Page

18

Share

COinS
 
 

To view the content in your browser, please download Adobe Reader or, alternately,
you may Download the file to your hard drive.

NOTE: The latest versions of Adobe Reader do not support viewing PDF files within Firefox on Mac OS and if you are using a modern (Intel) Mac, there is no official plugin for viewing PDF files within the browser window.